Power up and take first flats
Check the panel at the telescope
Section titled “Check the panel at the telescope”With panel power off, disconnect the optional ASIAIR control cable so the panel button can operate. On motorized models, park the telescope, clear the flap’s travel and start with the cover closed.
Choose a power supply
Section titled “Choose a power supply”Use a regulated 12 V DC supply. The supported range is 12–14 V. The plug is 5.5 × 2.1 mm, centre positive. Match the current rating below and follow the label on your panel or control box. A supply with a higher current rating is suitable at the correct voltage and polarity. The included USB-C cable carries data. Connect DC power separately.
| Your panel | Supply rating at 12 V | First test with the panel button |
|---|---|---|
| FP2 / OFP2 motorized cover with flat light | 3 A or more | Long-press to open. Press during travel to stop. Close the flap, then short-press to cycle the brightness presets. Check that the diffuser lights evenly. |
| SFP2 motorized solar or sky diffuser | 3 A or more | Long-press to open and close the diffuser. Check clearance and both end positions. The SFP2 uses light from the sky for flats. Keep the telescope’s required solar filtration in place. |
| FTL2 / FT2 / WFT2 light-only panels | 1 A or more | Connect power to the main input (on the control box for WFT2). Short-press to cycle the saved brightness levels and check that the surface lights evenly. |
Keep motorized covers powered while open. Removing DC power releases the motor’s holding torque. An open OFP2 or a folding flap held at a custom angle can move under gravity. Troubleshoot flashing light or stalled motion
Control from a computer
Section titled “Control from a computer”Use a USB-C data cable and the panel’s normal power supply. Start with a direct USB port on the computer. Download FP2 Control Panel v2.0.0 · ASCOM driver downloads
| Software | First connection |
|---|---|
| FP2 Control Panel | On Devices, select its card under Local devices. Test the cover or light controls fitted to your model. Disconnect before another application takes over the USB port. |
| NINA over USB | On Windows, install the ASCOM Platform and Deep Sky Dad flat-panel ASCOM driver. In Equipment → Flat Panel, select the Deep Sky Dad device, open its driver settings, select the panel port, and connect. |
| INDI | Add the Deep Sky Dad flat-panel driver to your equipment profile. Select the panel’s serial device and connect. Park the cover for flats and unpark it for imaging. |
For NINA over the network, use the Wi-Fi module’s Alpaca connection.
For illustrated connection steps and the six ASCOM driver profiles, see Control Panel, ASCOM and INDI.
Take a test flat in NINA
Section titled “Take a test flat in NINA”For an LED panel, close the illuminated flap or position the telescope facing the light-only panel. In the Flats Wizard, select one filter, your imaging gain and binning, and your usual target ADU. Start with Dynamic Exposure to hold the light level steady while the wizard finds an exposure. If your camera requires a particular exposure length, use Dynamic Brightness and let the wizard adjust the panel instead. For diffuser flats, see Install and operate the SFP2.
Inspect the first frame and histogram before running a series. Saturated flats need less light or a shorter exposure. If the app shows brightness as a percentage, its lowest nonzero setting can still be much brighter than the panel’s lowest native step. Test a low native setting in the Control Panel. Repeat for each filter.
On heater-equipped models, the heater warms the panel’s diffuser. Leave the default heater mode for a first test. A telescope corrector plate or objective has its own dew-control requirements. Cover heater modes and temperature control