Fit and install the panel
Measure the mounting point
Section titled “Measure the mounting point”- With the dew shield in its working position, measure straight across its outside edges at the place the insert will grip. Record the diameter in millimetres.
- Measure from the front edge back to the first screw head, raised rim, or accessory. Check the clear width all around the tube. For a truss or a special front plate, use the instructions for that telescope’s mounting kit.
- Check the opening path with the scope parked and the camera, guide scope, and cables fitted. In a remote observatory, include the largest permitted swing around the pier.
For example, a 130 mm telescope with a 155 mm dew shield needs an insert matched to 155 mm. Check that the body illuminates the full 130 mm aperture. If transferring a panel, also check its body size and insert revision. A ring made for a FLAP125 body will not seat in a FLAP100 body. A photo of the insert markings and a side view of the mounting area help support identify the correct part.

FP2 dimensions and drawings · OFP2 dimensions and drawings
Choose the FP2 opening direction
Section titled “Choose the FP2 opening direction”Park the telescope in the position you normally use to operate the flap. Check where the flap will open relative to the ground. The same installation can change orientation when the telescope moves.



| Panel model | Recommended opening directions |
|---|---|
| FLAP100 PRO, FLAP125 PRO | Top, side, or bottom |
| FLAP150 PRO, FLAP170 PRO, FLAP194 PRO | Top, side, or bottom. Bottom may require range calibration. |
| FLAP260 PRO XL, FLAP300 PRO XL, FLAP330 PRO XL | Top only |
Mount the folding FP2
Section titled “Mount the folding FP2”- With the panel unpowered, open the flap and slide the assembly onto the telescope.
- Align the insert lip flush with the edge of the dew shield.
- Tighten the mounting bolt by hand until the panel is secure. Excess force can crack the plastic.
- Close the flap before applying power.
Use the same telescope position each time you open or close the flap so the magnets engage consistently.

Mount the sideways-opening OFP2
Section titled “Mount the sideways-opening OFP2”Open the unpowered flap about 90°. Slide the ring onto the dew shield until the lip rests on the front edge. On rings with a triangle marker, use it to align the opened panel symmetrically about the mount’s declination axis. Check that the open flap clears the guide scope. Hand-tighten the bolt and close the panel before applying power.
Choose a park position that allows the magnets to engage without the flap hanging toward the ground. On a reversible OFP2 ring, changing the opening side also requires moving the limiter and repeating range calibration.
With the lip seated, orient the assembly toward the mount saddle. The open flap should sit symmetrically about the declination axis. Check this with all equipment fitted, especially on 8- and 10-inch instruments where the flap’s weight can flex the assembly.